BUS AS-Interface
Series / Model BUS AS-Interface
Apply to AS-Interface and be used to connet sensor with propeller.Apply to automobile and chemical industry,etc.
Overview
BUS AS-Interface
BUS AS-Interface 2X1.25mm² PVC IEC60332-1 ****m YY/MM/DD
Application
Apply to AS-Interface and be used to connet sensor with propeller.Apply to automobile and chemical industry,etc.
Technical Data
—Temperature Range
Fixed Application :
PVC : -40℃ ~80℃
TPE : -40℃ ~80℃
During the Installation :
PVC : -20℃ ~70℃
TPE : -40℃ ~80℃
—Test Voltage
2000V/min(AC)
—Rated Voltage
300V
—Insulation Resistance
≥1MOhm*km
—Minimum Bending Radius
Fixed Application : 10D (D=cable diameter)
Cable Construction
Conductor : Stranded tinned copper
Insulation : TPE
Color : Blue, brown
Jacket : See the table below
Color : Yellow
Properties
Flame resistance according to IEC60332-1
TPE jacket cable is extremely resistant to oil,abrasion and hydrolysis
Halogen free for TPE jacket cable
| ltem No. | Spec.( mm2) | Jackct | Nominal O.D. ( mm) | Cop.weight approx. (kg/km) | Weight approx.(kg/km) |
| ZL5107001 | 2x1.5 | pvc | 10mmx4mm | 30.0 | 70 |
| zL5107002 | 2×1.5 | TPE | 1ommx4mm | 30.0 | 66 |
Need help selecting a model or configuration?
Send load, speed, stroke, environment and interface requirements for model confirmation.